Acoustic Stud

Acoustic Stud Partitions

Libra Acoustic Stud is designed to give a cost-effective way to improve acoustic performance in both domestic and commercial installations. Partitions are constructed in exactly the same way as a standard C Stud partitions.

1. Install a single row of Libra Standard Tracks to the floor and soffit. Fix with suitable fasteners at maximum 600mm centres. Where deflection heads are required, install Libra Deep Tracks to the soffit with plasterboard strips and an intumescent mastic seal. Please note; minimum stud engagement to be 20mm.

2. Install Libra Acoustic Studs at abutments. Fix to the structure with suitable fasteners at maximum 600mm centres.

3. Seal the entire perimeter of the frame on both sides with beads of acoustic / intumescent mastic.

4. Form door openings.

5. Friction fit Libra Acoustic Studs at maximum 600mm centres (reduce to 400mm in tiled areas). Do not screw or crimp studs to deflection head channels.

6. Form service openings and frame out as required.

7. Install cavity insulation where required, fixed at the head as per manufacturers recommendations.

8. Install plasterboard linings as per specification with suitable drywall screws at maximum 300mm centres. Ensure all boards are aligned with the board joint indicator line. Boards to be fixed to their entire perimeter.


Product Code

Product Description

Stock Lengths mm

Weight per Length Kgs

FSA70/24

70mm Acoustic Stud x 0.5mm

Flange dimensions 50/48mm
24001.64

FSA70/27
27001.84

FSA70/30
30002.05

FSA70/36
36002.46

FSA70/42
42002.86

FSA92/27

92mm Acoustic Stud x 0.5mm

Flange dimensions 50/48mm
27002.08

FSA92/30
30002.31

FSA92/36
36002.77

FSA92/42
42003.23

Full list of technical drawings & details available upon request.